Molecular detection of mycobacterium tuberculosis complex from clinical sputum samples in patients attending tertiary care centre in Uttar Pradesh province of India


1 M.Sc Medical Microbiology 3rd Year, Department of Microbiology, TMMC&RC, Moradabad, India
2 Professor & H.O.D of Microbiology, TMMC&RC, Moradabad, India
3 PhD Scholar of Microbiology, TMMC&RC, Moradabad, India

Correspondence Address:
Surpati Kharibam
Department of Microbiology, TMMC&RC, Moradabad, U.P
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.5530/ami.2016.1.22

Rights and Permissions

Background: In the world, tuberculosis ranks second after HIV of all infectious agents leading cause of mortality and morbidity due to bacterial infections with HIV taking the first spot. India holds the global burden of TB in one fifth with more than 350,000 deaths each year. Though pulmonary TB (PTB) cases, account for the vast majority of the total TB burden, almost 10-15 per cent of total cases are extra-pulmonary infection. Methods: Mycobacterium Tuberculosis complex were detected in 50 clinical sputum samples by using Polymerase chain Reaction (PCR) and BacT/Alert. Results: In our study, 50 sputum clinical samples were taken, out of which 11(22%) were smear positive & 39 (78%) were smear negative. Out of 11 smear positive 10 (90%) were MTB (Mycobacterium Tuberculosis) & 01 (10%) was NTM (Non-Tuberculous mycobacteria) and in 39 smear negative,15 (38.47%) were M. tuberculosis & 02 (5.12%) were NTM and 22 (56.41%) samples were negative by using PCR. By BacT/Alert 3D system, out of 50 clinical samples only 15(30%) samples were positive and 35 (70%) samples were negative for M. tuberculosis complex. Conclusions: It is concluded that result obtained from our study, Mycobacterium tuberculosis complex was detected by PCR from clinical samples has high specificity (99%) and sensitivity (95%) than BacT/Alert 3D system.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed614    
    Printed17    
    Emailed0    
    PDF Downloaded53    
    Comments [Add]    

Recommend this journal